Department of
orthopedics operation microscope(orthopedics
surgical microscope,orthopedics
surgery microscope,orthopedics
operating microscope)
is the most striking feature of binocular on
hand mirror, namely the two doctors face under
the microscope of vascular suture operation.
Therefore the Department of orthopedics
operation microscope simultaneously suitable for replantation of severed finger hand surgery,
burns and plastic surgery, fallopian tube, vas
deferens, the breaking of Department of
gynaecology andrology. All vascular anastomosis
operation are applicable.
Performance characteristics:
1, double binocular on hand mirror, optical
path, the same magnification requirements, with
the market
2, according to the operation site selection of
magnification. General vascular anastomosis can
be magnified 10 times, and some small vessels
must be more than 16 times ( such as children's
finger capillary ) to facilitate operation.
Therefore, 5~25 times the stepless electric
continuous variable times as the best, second
third discontinuous zoom 6X10X16X. Fixed zoom 10
times as the basic requirements. Under normal
circumstances, the Department of orthopedics for
spine surgery, neurovascular complex. Request
with 5~25 times electric continuous zoom
system.Such as my company LZL-6A, and burn and
plastic parts, due to uncertainty range, are
likely to encounter complex neurovascular,
therefore also suggested the use of type LZL-6A.
3, for the convenience of operation, the band
X-Y planar mobile microscope best, moving range
( about 40 mm, before and after ) can be.
4, operation doctor hands busy, and aseptic
operation, thus the micro focus ( fine focus
range is 40mm. ) Plane move operation must use
foot controller, and it is best to use
waterproof switch.
5, a cold light source coaxial illumination,
light bulb to facilitate replacement, especially
in a stepless power zoom lens operation, must
have a conversion bulbs, such as my company's
LZL-6A four conversion bulb. Also can choose
xenon lighting, its life is longer. The
brightness of the illumination generally up to
30000Lx on the line, no continuous variable
times mirror can reach as high as above 60000Lx.
6, other indicators such as the working distance
of 200mm field diameterΦ 55~Φ 11, distance
regulation 54-75mm, visibility adjusting± 6D,
eyepiece magnification around 12.5X, these are
all within the international standard can, on a
little more, all without good or bad. According
to the need also to choose digital camera and
CCD camera, the operation data acquisition and
teaching to provide a convenient.
7, General requirements, frame with convenient
and flexible operation, compact and beautiful on
the line, no continuous variable times big
operation with mirror, frame to bully strong,
firm, mobile convenient, flexible operation,
complete function.
8, from the domestic market share, Department of
orthopedics, Department of plastic surgery,
higher education research, teaching 80% were
type LZL-6A, hand surgery, family planning and
dissection test with 80% XTS-4A is a portable
type. Different scopes, bring out the best in
each other.
Lucky bird - bring you lucky and auspicious
Narrator: medical equipment design engineer: Min
Jian
Contact: 13063513343
BACK |